Gold Member Since 2007
Audited Supplier
Shanghai Electric Group Busbar Trunking Co., Ltd.

On Load Switch, on-Load Breaker, Load Breaker manufacturer / supplier in China, offering Indoor Vacuum Type Load Break Switch, Jxf Jff Type Stainless Steel Cabinet Distribution Box Enclosure, Distribution Busbar Trunking Busduct System Bbt Power Bbt and so on.

(/ )

Supplier Homepage Product load break switch Indoor Vacuum Type Load Break Switch

Indoor Vacuum Type Load Break Switch

This product is currently unavailable, but you may contact the supplier directly, for further interest.
Basic Info
  • Model NO.: FZN
  • Operation: Electric Type
  • Arc-extinguishing Medium: Vacuum
  • Structure: Vertical
  • Type: Circuit Breaker
  • Certification: VDE, ISO9001-2000, CCC
  • Trademark: Shanghai Electric
  • Origin: Shanghai
  • Breaking Capacity: High Voltage Circuit Breakers
  • Speed: High-Speed Circuit Breaker
  • Installation: Fixed
  • Poles Number: 3
  • Function: Circuit-Breaker Failure Protection
  • Item: Indoor Vacuum Type Load Break Switch
  • Specification: IEC 62227-100, GB1984-2003
  • HS Code: 85389000
Product Description
The vacuum circuit breaker of FZN - 12/24 is a high voltage switchgear for indoor use, applying to three phases, AC. Supply of 50/60HZ, rated voltage 12KV/24KV. The vacuum load break switchis. The operating mechanism is of stored energy type by spring. It can be operated by AC. Supply or DC. Supply and also can be operated by hand.

This circuit breaker has advantages of simple structure, strong switch capacity, long service life, multi-function, free explosion and easy maintenance. It is applicable for controlling switch or protective switch of power distribution and transmission for power plants and transformer substations, especially applicable for breaking important load and frequent operations.

Applying ambient conditions
1. Ambient temperature: -10º C~+40º C.
2. The height above sea level: ≤ 1000m(besides the special requirements).
3. Relative humidity: The average humidity of a day should be no more than 95%; The average humidity of a month should be no more than 90%.
4. Saturated vapour pressure: The average pressure of a day should be no more than 2.2kPa; The average pressure of a month should be no more than 1.8kPa.
5. Earthquake intensity: Not exceed 8 degrees.
6. It should be installed in the places without fire, explosion, serious filth, chemical erosion and violent vibration.